Promega Corporation

PowerPlex® 21 System

Faster process. Flexible protocols. Unbeatable results.

A fast and flexible 21-plex for casework, paternity and database testing, the PowerPlex® 21 System provides:

  • Rapid thermal cycling, saving time with every run
  • Unbeatable inhibitor tolerance, enabling analysis of challenging casework samples
  • Optimized protocols for many sample types, including direct amplification from FTA® cards, as well as pretreated non FTA® card punches or swabs
10189TA Figure 1. Configuration of the PowerPlex® 21 System. The PowerPlex® 21 System contains all of the 13 CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX and vWA, plus Amelogenin, Penta D, Penta E, D1S1656, D2S1338, D6S1043, D12S391 and D19S433.

The PowerPlex® 21 System contains all of the 13 CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX and vWA, plus Amelogenin, Penta D, Penta E, D1S1656, D2S1338, D6S1043, D12S391 and D19S433.

/~/media/images/resources/figures/10100-10199/10189ta_600px.jpg?la=en&w=600&h=243&as=1
10247TA_600px Figure 2. The PowerPlex® 21 System. A single-source template DNA (0.5ng) was amplified using the PowerPlex® 21 System and analyzed with an Applied Biosystems 3130 Genetic Analyzer using a 3kV, 5-second injection. Results were analyzed using GeneMapper® ID software, version 3.2. Panel A. The fluorescein-labeled loci. Panel B. The JOE-labeled loci. Panel C. The TMR-ET-labeled loci. Panel D. The CXR-ET-labeled loci. Panel E. The CC5 Internal Lane Standard 500.

Panel A. The fluorescein-labeled loci. Panel B. The JOE-labeled loci. Panel C. The TMR-ET-labeled loci. Panel D. The CXR-ET-labeled loci. Panel E. The CC5 Internal Lane Standard 500.

/~/media/images/resources/figures/10200-10299/10247ta_600px.jpg?la=en&w=601&h=362&as=1

Unbeatable Inhibitor Tolerance

The PowerPlex® 21 System is more tolerant of PCR inhibitors than other STR systems including the PowerPlex® 16 HS System. This allows more interpretable data and less need for re-amplification of samples previously deemed "difficult" due to the presence of inhibitors.

Figure 3. Human genomic DNA (500pg; n = 3) was amplified with the PowerPlex ® 16 HS and 21 Systems in the presence of common inhibitors such as hematin, humic acid and tannic acid. Percent of alleles called are indicated.

~/media/Images/Resources/Figures/10300-10399/10366MA_800px.ashx

Flexibility for Most Sample Types

The PowerPlex® 21 System is designed to work with a variety of sample types, including difficult casework samples and is compatible with direct amplification from FTA® card punches as well as pretreated swabs and Bode Buccal Collector™ device or S&S 903 punches.

Amplified products were separated on an Applied Biosystems 3130 Genetic Analyzer (3kV, 5-second injection).

~/media/Images/Resources/Figures/10300-10399/10363TA_900px.ashx

Amplified products were separated on Applied Biosystems 3130 Genetic Analyzer (3kV, 5-second injection).

~/media/Images/Resources/Figures/10300-10399/10364TA_900px.ashx

Amplified products were separated on an Applied Biosystems 3130xl Genetic Analyzer (3kV, 5-second injection).

~/media/Images/Resources/Figures/10300-10399/10365TA_900px.ashx

Amplified products were separated on an Applied Biosystems 3130xl Genetic Analyzer (3kV, 5-second injection).

~/media/Images/Resources/Figures/10300-10399/10366TA_900px.ashx
Figure 4. Upper Left (4a): Amplification of 500pg of human genomic DNA using the recommended protocol. Amplified products were separated on an Applied Biosystems 3130 Genetic Analyzer (3kV, 5-second injection). Upper Right (4b): Direct amplification of one 1.2mm punch from blood on an FTA card using recommended protocol. Amplified products were separated on Applied Biosystems 3130 Genetic Analyzer (3kV, 5-second injection). Bottom Left (4c): A 1.2mm punch from buccal samples on S&S 903 was pre-treated with prototype PunchSolution™ reagent, then amplified using the recommended protocol. Amplified products were separated on an Applied Biosystems 3130xl Genetic Analyzer (3kV, 5-second injection). Bottom Right (4d): A swab from buccal samples was pre-treated with SwabSolution™ reagent, then amplified using the recommended protocol. Amplified products were separated on an Applied Biosystems 3130xl Genetic Analyzer (3kV, 5-second injection).

Upper Left: Amplification of 500pg of human genomic DNA using the recommended protocol. Amplified products were separated on an Applied Biosystems 3130 Genetic Analyzer (3kV, 5-second injection). Upper Right: Direct amplification of one 1.2mm punch from blood on an FTA card using recommended protocol. Amplified products were separated on Applied Biosystems 3130 Genetic Analyzer (3kV, 5-second injection). Bottom Left: A 1.2mm punch from buccal samples on S&S 903 was pre-treated with SwabSolution™, then amplified using the recommended protocol. Amplified products were separated on an Applied Biosystems 3130xl Genetic Analyzer (3kV, 5-second injection). Bottom Right: A swab from buccal samples was pre-treated with SwabSolution™, then amplified using the recommended protocol. Amplified products were separated on an Applied Biosystems 3130xl Genetic Analyzer (3kV, 5-second injection).

~/media/Images/Resources/Figures/10300-10399/10363TA-10365TA_800px.ashx
  • Warning
  • It appears that you have Javascript disabled. Our website requires Javascript to function correctly. Please enable Javascript to experience our website.

Scientists at Your Service

We offer a range of services to help you succeed using Promega technologies. From product training to set up of automated systems and development of custom applications—our scientific support goes beyond the basics.

Ask us! We are here to help you.

Click Here for Technical Questions and Ordering Support »